Honeywell Fan Limit Insertion Controls


All available Cam Stat Controls
L-59 Series
These limit controls have SPDT switches that incorporate a fi xed temperature setting. Consult factory for fi xed settings. Pilot Duty: N.C. Contacts: 40 VA at 30, 120 and 240 VAC, N.O. Contacts: 120 VA at 30, 120 and 240 VAC.
High Limit Only
High Limit Only

FALTS Series-High Limit, Fan Time Delay
Include a time start fan control ("heat assist"). The time delay turns on the blower as a function of time and/or temperature after the room thermostat calls for heat and turns off the blower as a function of temperature at the indicated dial setting of the fan. The limit portion will limit the temperature of the furnace to a safe operating temperature. A limit temperature adjustment is provided to match the setting of the old device being replaced. Electrical rating: Timer ("Heat Assist"): 0.08 amps at 24 VAC.

Pilot Duty: 40 VA at 30 VAC & 120 VAC


FAL Series- Universal Replacement
Universal replacements for application in all types of forced air heating furnaces. The fan portion incorporates an adjustable fan "OFF" setting and an adjustable differential to enable the installer to match the settings of the old device being replaced.






Heating Categories

BOILERS:

Controls
Pumps
Electric Zone Valves
Pneumatic Zone Valve
Air-Vents/Purgers
Expansion Tank
Vent Damper
Thermostat

GAS FURNACE:

Thermocouple
Controls
Ignition Controller
Gas Burners
Motors
Hot Surface Ignitors
Gas Burners
Blowers
Thermostat
Draft Inducers
Valves

HEAT PUMP:
Controls
Motors
Thermostat

OIL FURNACE:

Pumps
Controls
Motors
Oil Burners
Tanks
Thermostat
Nozzles
Motors
Transformers
Flame Relays
Electrodes
Barometric Damper

Keyword searches work best with single words

Part number search only need the first 3 or 4 characters


More Information
Change of Season
Spring and fall are a challenge for your equipment to maintain comfort in the building

Need help NOW!!!
Our experienced technicians have over 20+ years in the field servings

Cracked Heat Exchanger
This is one I always hated telling the customer, "You have a cracked heat exchanger and your furnace has to be replaced,...Today."

My Furnace burner cycles on and off
There two things that normally cause burner short cycling

Oil Burner Flame Failure
Oil burners will shut down and require a manual reset.

Residential boiler maintenace
September is the time to get your boiler ready for the winter.